Skip to content

Chassis resource definitions of iLO 6 v1.69

For each data type provided by the HPE ilO Redfish service, find below its description including the list of possible instances (URIs), links to related other resources, described properties and many other details.

Refer to the data types and collection section for more information on Redfish data types and collections.

ChassisCollection

@odata.type: "#ChassisCollection.ChassisCollection"

A Collection of Chassis resource instances.

Resource Instances

UriHTTP Allow
/redfish/v1/chassisGET
Link NameDestination type
Members[]Chassis

Members (array)

Member of ChassisCollection.ChassisCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of ChassisCollection.ChassisCollection

Typestring
Read OnlyTrue
AddediLO6 1.05
Formaturi-reference

Members@odata.count

Member of ChassisCollection.ChassisCollection

DescriptionThe total number of collection members.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Chassis

@odata.type: "#Chassis.v1_25_1.Chassis"

The Chassis resource describes the physical components for a system. This object represents rack mount servers, blades, and all other containers. The non-CPU/device-centric parts of the schema are accessed either directly or indirectly through this resource.

Resource Instances

UriHTTP Allow
/redfish/v1/chassis/{item}GET PATCH
Link NameDestination type
Links/ComputerSystems[]ComputerSystem
ThermalSubsystemThermalSubsystem
FallbackSensorsCollection of Sensor
Links/ManagedBy[]Manager
Oem/Hpe/Links/DevicesCollection of HpeServerDevice
SensorsCollection of Sensor
NetworkAdaptersCollection of NetworkAdapter
PowerPower
ThermalThermal
EnvironmentMetricsEnvironmentMetrics

AssetTag

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis user-assigned asset tag.
Typestring or null
Read OnlyFalse
AddediLO6 1.05

ChassisType

Member of Chassis.v1_25_1.Chassis

DescriptionThis property indicates the physical form factor type of this resource.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
RackAn equipment rack, typically a 19-inch wide freestanding unit.
BladeAn enclosed or semi-enclosed, typically vertically-oriented, system chassis that must be plugged into a multi-system chassis to function normally.
EnclosureA generic term for a chassis that does not fit any other description.
StandAloneA single, free-standing system, commonly called a tower or desktop chassis.
RackMountA single system chassis designed specifically for mounting in an equipment rack.
CardA loose device or circuit board intended to be installed in a system or other enclosure.
CartridgeA small self-contained system intended to be plugged into a multi-system chassis.
RowA collection of equipment racks.
PodA collection of equipment racks in a large, likely transportable, container.
ExpansionA chassis that expands the capabilities or capacity of another chassis.
SidecarA chassis that mechanically connects with another chassis to expand its capabilities or capacity.
ZoneA logical division or portion of a physical chassis that contains multiple devices or systems that cannot be physically separated.
SledAn enclosed or semi-enclosed, system chassis that must be plugged into a multi-system chassis to function normally similar to a blade type chassis.
ShelfAn enclosed or semi-enclosed, typically horizontally-oriented, system chassis that must be plugged into a multi-system chassis to function normally.
StorageEnclosureA chassis that encloses storage.
OtherA chassis that does not fit any of these definitions.

Drives

The link to the collection of drives within this chassis Drives is a link ("@odata.id": URI) to another resource.

EnvironmentMetrics

The link to the environment metrics for this chassis. EnvironmentMetrics is a link ("@odata.id": URI) to another resource.

EnvironmentalClass

Member of Chassis.v1_25_1.Chassis

DescriptionThe ASHRAE Environmental Class for this chassis.
Typestring or null
Read OnlyFalse
AddediLO6 1.10

The following are the supported values:

ValueDescription
A2ASHRAE Environmental Class 'A2'.
A3ASHRAE Environmental Class 'A3'.
A4ASHRAE Environmental Class 'A4'.

Location

Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of Chassis.v1_25_1.Chassis

DescriptionThe number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2.
Typeinteger or null
Read OnlyTrue
AddediLO6 1.10

Location.PartLocation.LocationType Member of Chassis.v1_25_1.Chassis

DescriptionThe location types for PartLocation.
Typestring or null
Read OnlyTrue
AddediLO6 1.10

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
SlotThe slot as the type of location.
BayThe bay as the type of location.
ConnectorThe connector as the type of location.
SocketThe socket as the type of location.
EmbeddedEmbedded within a part.

Location.PartLocation.Orientation Member of Chassis.v1_25_1.Chassis

DescriptionThe orientation for the ordering of the part location ordinal value.
Typestring or null
Read OnlyTrue
AddediLO6 1.10

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
FrontToBackThe ordering for LocationOrdinalValue is front to back.
BackToFrontThe ordering for the LocationOrdinalValue is back to front.
TopToBottomThe ordering for the LocationOrdinalValue is top to bottom.
BottomToTopThe ordering for LocationOrdinalValue is bottom to top.
LeftToRightThe ordering for the LocationOrdinalValue is left to right.
RightToLeftThe ordering for the LocationOrdinalValue is right to left.

Location.PartLocation.Reference Member of Chassis.v1_25_1.Chassis

DescriptionThe reference area for the location of the part.
Typestring or null
Read OnlyTrue
AddediLO6 1.10

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
TopThe part is in the top of the unit.
BottomThe part is in the bottom of the unit.
FrontThe part is in the front of the unit.
RearThe part is in the rear of the unit.
LeftThe part is on the left side of of the unit.
RightThe part is on the right side of the unit.
MiddleThe part is in the middle of the unit.

Location.PartLocation.ServiceLabel Member of Chassis.v1_25_1.Chassis

DescriptionThe label of the part location, such as a silk-screened name or a printed label.
Typestring or null
Read OnlyTrue
AddediLO6 1.10

Location.Placement Location.Placement.AdditionalInfo Member of Chassis.v1_25_1.Chassis

DescriptionArea designation or other additional info.
Typestring or null
Read OnlyFalse
AddediLO6 1.10

Location.Placement.Rack Member of Chassis.v1_25_1.Chassis

DescriptionThe name of a rack location within a row.
Typestring or null
Read OnlyFalse
AddediLO6 1.10

Location.Placement.RackOffset Member of Chassis.v1_25_1.Chassis

DescriptionThe vertical location of the item, in terms of RackOffsetUnits.
Typeinteger or null
Read OnlyFalse
AddediLO6 1.10

Location.Placement.RackOffsetUnits Member of Chassis.v1_25_1.Chassis

DescriptionThe type of rack unit in use.
Typestring or null
Read OnlyFalse
AddediLO6 1.10

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
OpenUA rack unit that is equal to 48 mm (1.89 in).
EIA_310A rack unit that is equal to 1.75 in (44.45 mm).

Location.Placement.Row Member of Chassis.v1_25_1.Chassis

DescriptionThe name of the row.
Typestring or null
Read OnlyFalse
AddediLO6 1.10

LocationIndicatorActive

Member of Chassis.v1_25_1.Chassis

DescriptionAn indicator allowing an operator to physically locate this resource.
Typeboolean or null
Read OnlyFalse
AddediLO6 1.10

Manufacturer

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis manufacturer.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

Model

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis model number.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

NetworkAdapters

The collection of network adapters contained within this chassis. NetworkAdapters is a link ("@odata.id": URI) to another resource.

Oem.Hpe.BayNumber

Member of Chassis.v1_25_1.Chassis

DescriptionThe bay number of the node or the blade.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.BaysConsumedHeight

Member of Chassis.v1_25_1.Chassis

DescriptionThe number of enclosure bays this chassis consumes in height.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.BaysConsumedWidth

Member of Chassis.v1_25_1.Chassis

DescriptionThe number of enclosure bays this chassis consumes in width.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.ChassisInputPowerWatts

Member of Chassis.v1_25_1.Chassis

DescriptionThe total input power consumed by the chassis and nodes.
Typeinteger
Read OnlyTrue
AddediLO6 1.61

Oem.Hpe.ChassisPowerWatts

Member of Chassis.v1_25_1.Chassis

DescriptionThe total power consumed by the chassis and nodes.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.ElConfigOverride

Member of Chassis.v1_25_1.Chassis

DescriptionThe value indicates if Thermal Configuration includes Edgeline specific options.
Typeboolean
Read OnlyFalse
AddediLO6 1.05

Oem.Hpe.EnclosureCPLD

Member of Chassis.v1_25_1.Chassis

DescriptionThe CPLD version of the enclosure.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.EnclosureDateTime

Member of Chassis.v1_25_1.Chassis

DescriptionThe date and time in a Moonshot EL chassis (enclosure).
Typestring
Read OnlyFalse
AddediLO6 1.05
Formatdate-time

Oem.Hpe.EnclosureIndicatorLED

Member of Chassis.v1_25_1.Chassis

DescriptionThe enclosure indicator LED that is used to identify the enclosure.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
UnknownThe state of the Indicator LED cannot be determined.
LitThe Indicator LED is on.
BlinkingThe Indicator LED is blinking.
OffThe Indicator LED is off.

Oem.Hpe.EnclosureModel

Member of Chassis.v1_25_1.Chassis

DescriptionType of enclosure.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.EnclosureUUID

Member of Chassis.v1_25_1.Chassis

DescriptionThe UUID of the enclosure.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware

Oem.Hpe.Firmware.ChassisControllerVersion Oem.Hpe.Firmware.ChassisControllerVersion.Current Oem.Hpe.Firmware.ChassisControllerVersion.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the chassis controller.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice.Current Oem.Hpe.Firmware.CpuMezzProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the CPLD.
Typestring
Read OnlyTrue
AddediLO6 1.10

Oem.Hpe.Firmware.PlatformDefinitionTable Oem.Hpe.Firmware.PlatformDefinitionTable.Current Oem.Hpe.Firmware.PlatformDefinitionTable.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe version of the Intelligent Platform Abstraction Data.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.PowerManagementController Oem.Hpe.Firmware.PowerManagementController.Current Oem.Hpe.Firmware.PowerManagementController.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the Power Monitor.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.PowerManagementControllerBootloader Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.Family Member of Chassis.v1_25_1.Chassis

DescriptionThe family type of the Power Monitor hardware.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.PowerManagementControllerBootloader.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the Power Monitor boot loader.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.SASProgrammableLogicDevice Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current Oem.Hpe.Firmware.SASProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the SAS controller.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.SPSFirmwareVersionData Oem.Hpe.Firmware.SPSFirmwareVersionData.Current Oem.Hpe.Firmware.SPSFirmwareVersionData.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe SPS FW Version number, aka ME FW Version, AAAA.BBBB.CCCC.DDDD.E
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice.Current Oem.Hpe.Firmware.SecondarySystemProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the CPLD.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Firmware.SystemProgrammableLogicDevice Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current Oem.Hpe.Firmware.SystemProgrammableLogicDevice.Current.VersionString Member of Chassis.v1_25_1.Chassis

DescriptionThe firmware version of the CPLD.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.IPv4Address

Member of Chassis.v1_25_1.Chassis

DescriptionThe IPv4 address of the chassis manager.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Images

Oem.Hpe.Images.Front Oem.Hpe.Images.Front.extref Member of Chassis.v1_25_1.Chassis

DescriptionThe URI of an external resource.
Typestring
Read OnlyTrue
AddediLO6 1.05
Formaturi-reference

Oem.Hpe.Images.Model Oem.Hpe.Images.Model.extref Member of Chassis.v1_25_1.Chassis

DescriptionThe URI of an external resource.
Typestring
Read OnlyTrue
AddediLO6 1.05
Formaturi-reference

Oem.Hpe.Location

Oem.Hpe.Location.GeographicLocation Oem.Hpe.Location.GeographicLocation.RackName Member of Chassis.v1_25_1.Chassis

DescriptionThe name of the chassis enclosure.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack Oem.Hpe.Location.LocationInRack.RackLdsPartNumber Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack part number.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.RackLdsProductDescription Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack product description.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.RackUHeight Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack U height.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.RackUUID Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack UUID.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.TagVersion Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack tag version.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.ULocation Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis rack U location.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationInRack.UPosition Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis U position in the rack.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.Location.LocationOfChassis Oem.Hpe.Location.LocationOfChassis.UUID Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis UUID provided by SMBIOS.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.MCTPEnabledOnServer

Member of Chassis.v1_25_1.Chassis

DescriptionIndicates if MCTP is enabled on the server or not.
Typeboolean
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.NodePowerWatts

Member of Chassis.v1_25_1.Chassis

DescriptionThe total power being consumed by this node.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.OnboardAdministrator

Oem.Hpe.OnboardAdministrator.IPv4Address Member of Chassis.v1_25_1.Chassis

DescriptionIPv4 address of the chassis.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.OnboardAdministrator.IPv6 Oem.Hpe.OnboardAdministrator.IPv6.DHCPv6Address (array) Member of Chassis.v1_25_1.Chassis

DHCPv6Address is an array containing elements of:

DHCPv6Address[{item}] Member of Chassis.v1_25_1.Chassis

Typestring
Read OnlyTrue
AddediLO6 1.05
Formatipv6

Oem.Hpe.OnboardAdministrator.IPv6.SLAACAddress (array) Member of Chassis.v1_25_1.Chassis

SLAACAddress is an array containing elements of:

SLAACAddress[{item}] Member of Chassis.v1_25_1.Chassis

Typestring
Read OnlyTrue
AddediLO6 1.05
Formatipv6

Oem.Hpe.OnboardAdministrator.IPv6.StaticAddress (array) Member of Chassis.v1_25_1.Chassis

StaticAddress is an array containing elements of:

StaticAddress[{item}] Member of Chassis.v1_25_1.Chassis

Typestring
Read OnlyTrue
AddediLO6 1.05
Formatipv6

Oem.Hpe.OnboardAdministrator.MacAddress Member of Chassis.v1_25_1.Chassis

DescriptionMAC address of the chassis.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.PcieMini2SlotRiser

Member of Chassis.v1_25_1.Chassis

DescriptionPCIE mini 2 slot riser is a platform dependent value used to identify installation of this riser.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
NotInstalledThe PCIE mini 2 slot riser is not installed. The PCIE mini slot 3 and slot 4 do not exist in this Enclosure.
InstalledWithOtherFRUA non recognized riser option is installed with a valid EEPROM FRU. Contact Customer Support to secure a replacement.
InstalledWithBadFRUThe PCIe mini 2 slot riser is installed with an invaild EEPROM FRU. Contact Customer Support to secure a replacement.
InstalledThe PCIE mini 2 slot riser is installed. The PCIE mini slot 3 and slot 4 exist in this Enclosure.

Oem.Hpe.PowerAlertMode

Oem.Hpe.PowerAlertMode.Activated Member of Chassis.v1_25_1.Chassis

DescriptionThe power alert mode activation state.
Typeboolean
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.PowerAlertMode.AlertPowerWatts Member of Chassis.v1_25_1.Chassis

DescriptionThe power consumption of the system when operating in alert mode.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.PowerAlertMode.SpikeWatts Member of Chassis.v1_25_1.Chassis

DescriptionMaximum additional power consumed when all CPUs are in Turbo Mode
Typeinteger
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.RackName

Member of Chassis.v1_25_1.Chassis

DescriptionThe name of the rack that contains the enclosure.
Typestring
Read OnlyTrue
AddediLO6 1.05

Oem.Hpe.SmartStorageBattery (array)

Member of Chassis.v1_25_1.Chassis

SmartStorageBattery is an array containing elements of:

SmartStorageBattery[{item}].BatteryWearLevelPercent Member of Chassis.v1_25_1.Chassis

DescriptionThe battery wear level percentage. When this value reaches 100%, the battery is completely worn out and needs to be replaced. The value is null if battery wear level cannot be determined or is not supported.
Typeinteger or null
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].ChargeLevelPercent Member of Chassis.v1_25_1.Chassis

DescriptionState of charge of the battery.
Typeinteger or null
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].ErrorCode Member of Chassis.v1_25_1.Chassis

DescriptionError code of the battery.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
NullA value is temporarily unavailable
GeneralFailureThe battery has failed.
HighInternalBatteryResistanceThe battery has failed due to high internal resistance.
LowOpenCircuitVoltageThe battery has failed due to a low voltage output.
BatteryCellFailureThe battery has failed.
BatteryChargeTimeoutThe battery did not charge at the expected rate, indicating a faulty battery.
OverTemperatureThe battery was disabled due to high ambient temperature, and will be re-enabled when the temperature is lowered.
DischargeBelowMinimumVoltageThe battery discharged below the minimum discharge voltage, and may be re-enabled upon recharging the battery.
DischargeCurrentHighThe last backup failed due to exceeding the maximum discharge current.
LoadCountExceededThe battery was disabled due to exceeding the maximum amount of devices supported, and will be re-enabled when the battery has been recharged or the additional devices are removed.
BackupSucceededThe last backup succeeded within the expected time.
OverCurrentThe battery has been protected due to exceeding the output current capability. The battery should be re-enabled on the next reboot.
PermanentFailureThe battery has permanently failed.
BackupTimeExceededThe last backup failed due to exceeding the battery discharge time limit.

SmartStorageBattery[{item}].FailurePredicted Member of Chassis.v1_25_1.Chassis

DescriptionIs this battery currently predicting a failure in the near future.
Typeboolean or null
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].FirmwareVersion Member of Chassis.v1_25_1.Chassis

DescriptionFirmware version of the battery.
Typestring
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].Index Member of Chassis.v1_25_1.Chassis

DescriptionIndex of the battery.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].MaximumCapWatts Member of Chassis.v1_25_1.Chassis

DescriptionMaximum capacity of the battery in watts.
Typeinteger
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].Model Member of Chassis.v1_25_1.Chassis

DescriptionModel of the battery.
Typestring
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].ProductName Member of Chassis.v1_25_1.Chassis

DescriptionProduct name of the battery.
Typestring
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].RemainingChargeTimeSeconds Member of Chassis.v1_25_1.Chassis

DescriptionRemaining charging time of the battery in seconds.
Typeinteger or null
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].SerialNumber Member of Chassis.v1_25_1.Chassis

DescriptionSerial number of the battery.
Typestring
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].SparePartNumber Member of Chassis.v1_25_1.Chassis

DescriptionSpare part number of the battery.
Typestring
Read OnlyTrue
AddediLO6 1.05

SmartStorageBattery[{item}].Status Member of Chassis.v1_25_1.Chassis See the Redfish standard schema and specification for information on common Status object.

Oem.Hpe.SystemMaintenanceSwitches

Oem.Hpe.SystemMaintenanceSwitches.Sw1 Member of Chassis.v1_25_1.Chassis

DescriptionOverride iLO security.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OniLO Security Override Enabled.
OffNo function (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw10 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw11 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw12 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw2 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw3 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw4 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw5 Member of Chassis.v1_25_1.Chassis

DescriptionBIOS/UEFI Password Disable.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnPower On Password disabled.
OffPower On Password enabled (Normal).

Oem.Hpe.SystemMaintenanceSwitches.Sw6 Member of Chassis.v1_25_1.Chassis

DescriptionReset Configuration.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
On
Off

Oem.Hpe.SystemMaintenanceSwitches.Sw7 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Default).

Oem.Hpe.SystemMaintenanceSwitches.Sw8 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Default).

Oem.Hpe.SystemMaintenanceSwitches.Sw9 Member of Chassis.v1_25_1.Chassis

DescriptionReserved.
Typestring
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
OnSwitch is on.
OffSwitch is off (Default).

Oem.Hpe.TelcoModeEnabled

Member of Chassis.v1_25_1.Chassis

DescriptionThis property indicates if Telco mode is enabled on the server.
Typeboolean or null
Read OnlyFalse
AddediLO6 1.10

Oem.Hpe.TrayID

Member of Chassis.v1_25_1.Chassis

DescriptionTray ID is a platform dependent value used to identify what kind of server tray it is.
Typestring
Read OnlyTrue
AddediLO6 1.05

PCIeDevices

The link to the collection of PCIe devices located in this chassis. PCIeDevices is a link ("@odata.id": URI) to another resource.

PCIeSlots

The link to the PCIe slot properties for this chassis. PCIeSlots is a link ("@odata.id": URI) to another resource.

PartNumber

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis part number.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

PhysicalSecurity

PhysicalSecurity.IntrusionSensor Member of Chassis.v1_25_1.Chassis

DescriptionThis indicates the known state of the physical security sensor, such as if it is hardware intrusion detected.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
NormalNo abnormal physical security conditions are detected at this time.
HardwareIntrusionA door, lock, or other mechanism protecting the internal system hardware from being accessed is detected as being in an insecure state.
TamperingDetectedPhysical tampering of the monitored entity is detected.

PhysicalSecurity.IntrusionSensorReArm Member of Chassis.v1_25_1.Chassis

DescriptionThis indicates how the Normal state to be restored.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

ValueDescription
ManualThis sensor would be restored to the Normal state by a manual re-arm.
AutomaticThis sensor would be restored to the Normal state automatically as no abnormal physical security conditions are detected.

Power

A reference to the thermal metrics (power supplies, power policies, sensors) for this chassis. Power is a link ("@odata.id": URI) to another resource.

PowerState

Member of Chassis.v1_25_1.Chassis

DescriptionThis is the current power state of the chassis.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

The following are the supported values:

Value
Null
On
Off
Unknown
Reset

SKU

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis SKU.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

Sensors

The link to the collection of sensors located in the equipment and sub-components. Sensors is a link ("@odata.id": URI) to another resource.

SerialNumber

Member of Chassis.v1_25_1.Chassis

DescriptionThe chassis serial number.
Typestring or null
Read OnlyTrue
AddediLO6 1.05

SparePartNumber

Member of Chassis.v1_25_1.Chassis

DescriptionThe spare part number of the chassis.
Typestring or null
Read OnlyTrue
AddediLO6 1.54

Status

Member of Chassis.v1_25_1.Chassis See the Redfish standard schema and specification for information on common Status object.

Thermal

A reference to the thermal metrics (fans, cooling, sensors) for this chassis. Thermal is a link ("@odata.id": URI) to another resource.

ThermalSubsystem

The link to the thermal subsystem properties for this chassis. ThermalSubsystem is a link ("@odata.id": URI) to another resource.

Actions

HpeServerChassis.DisableMCTPOnServer Member of Chassis.v1_25_1.Chassis There are no parameters for this action.

HpeServerChassis.FactoryResetMCTP Member of Chassis.v1_25_1.Chassis There are no parameters for this action.

HpeServerChassis.ModifyEnclosureChassisFru Member of Chassis.v1_25_1.Chassis The action to modify field of enclosure chassis FRU.

Parameters:

PartNumber (string)

Part Number of the enclosure chassis.

SerialNumber (string)

Serial Number of the enclosure chassis.